Module 6 · Fluid mechanics and machinery

Laminar and turbulent flow

Smooth layered flow or chaotic swirling flow — the Reynolds number tells you which you will get.

Notes
On this page
  1. The idea
  2. Everyday intuition
  3. How it works
  4. Key formulas
  5. Worked example
  6. Where it is used
  7. Common misconceptions
  8. Self-check

The idea

Slow or very viscous flow is : the fluid moves in smooth layers. Fast flow becomes : swirling eddies mix it. The Re = ρVD/μ compares the fluid’s inertia with its viscosity; in a round pipe flow is laminar below about 2 300 and turbulent above about 4 000.

Everyday intuition

Smoke from a candle first rises in a smooth straight thread (laminar), then a little higher breaks into wild curls (turbulent) as it speeds up.

How it works

  1. Reynolds number. Inertia (ρV²) ÷ viscous stress (μV/D) = ρVD/μ = VD/ν. Big Re: inertia wins and small disturbances grow into eddies.
  2. Pipe flow regimes. Re < 2 300 laminar; 2 300–4 000 transitional; above 4 000 turbulent. Most water pipes run at Re of 10⁴–10⁶, so they are turbulent.
  3. Velocity profiles. Laminar pipe flow has a parabola-shaped profile (centre speed twice the mean). Turbulent flow has a flatter profile with a steep drop near the wall.
  4. Consequences. Turbulence greatly increases mixing, heat transfer and friction loss.
  5. Same Re, same flow pattern. Two geometrically similar flows with the same Re behave alike — the basis of wind-tunnel models.
parabola flatter

Turbulent — eddies and a flatter profile.

Laminar against turbulent flow in a pipe. Tap each part. Laminar and turbulent pipe flow. Original diagram drawn for this site. Tap labelled parts for an explanation.
Laminar and turbulent pipe flow

Key formulas

Reynolds number for pipe flow:

Re=ρVDμ=VDνRe = \dfrac{\rho V D}{\mu} = \dfrac{V D}{\nu}
ReRe
Reynolds number none
DD
pipe diameter m
VV
mean speed m/s

Worked example

Where it is used

  • Pipe and duct design: Re sets which friction formula to use.
  • Heat exchangers: designers want turbulence for better heat transfer.
  • Model testing: ships, cars and aircraft models are tested at matching Re (or as close as possible).
  • Medicine and microfluidics: blood in small vessels and flow in lab-on-a-chip devices are laminar.

Common misconceptions

Self-check

Check What is Re for water (ν = 10⁻⁶ m²/s) at 0.5 m/s in a 20 mm pipe, and what is the regime?

Show answer

Re = 0.5 × 0.02/10⁻⁶ = 10 000: turbulent.

Check Which flow transfers heat better, laminar or turbulent?

Show answer

Turbulent, because eddies mix hot and cold fluid.

Check Why must a model aircraft be tested at the same Reynolds number as the real one?

Show answer

Flows with the same Re have the same pattern of viscous and inertial effects, so the forces scale correctly.