Module 5 · Heat transfer · Summary
Module 5 summary: heat transfer
The whole module on one printable page.
On this page
Big ideas
- Three ways heat moves: conduction through materials, convection by moving fluids, radiation by infrared waves. All go from hot to cold.
- Conduction: Fourier’s law Q̇ = kAΔT/L. Metals conduct well; still gas conducts poorly, which is why insulation traps air.
- Convection: Q̇ = hA(T_s − T_∞). h depends on the flow, not just the fluid: fans, pumps and boiling raise it.
- Radiation: εσA(T_s⁴ − T_sur⁴) with temperatures in kelvin. Shiny surfaces emit and absorb little.
- Thermal resistance: treat heat like current. Layers in series add (L/kA and 1/hA); the U-value is 1/(AΣR).
- Fins add area where h is low; they are worth it only while mL is below about 2–3.
- Heat exchangers: Q̇ = UAΔT_lm. Counterflow does the most with a given area; fouling lowers U over time.
Formula sheet
| Formula | Notes | |
|---|---|---|
| Fourier’s law of conduction | Steady, one-dimensional conduction through a flat slab; heat flows from hot to cold. | |
| Newton’s law of cooling (convection) | h is found from experiments or correlations; it depends on the fluid, speed and shape. | |
| Heat from a fin with an insulated tip | m = √(hP/(kA_c)); θ_b = T_base − T_∞. Uniform cross-section, steady, 1-D along the fin. | |
| Fin efficiency | Actual heat ÷ heat if the whole fin were at the base temperature; insulated tip. | |
| Heat exchanger duty and log-mean temperature difference | ΔT₁ and ΔT₂ are the hot-minus-cold differences at the two ends of the exchanger. | |
| Net radiation from a small grey surface | A small surface inside large surroundings; temperatures in kelvin; σ = 5.67 × 10⁻⁸ W/(m²·K⁴). | |
| Thermal resistances | Heat flow = temperature difference ÷ resistance, like current = voltage ÷ resistance. | |
| Layers in series and the U-value | Same heat flow through every layer (steady state, no heat generated inside). |
Typical values used in this module
| Quantity | Typical value | Source |
|---|---|---|
| Thermal conductivity k (W/(m·K)) | copper ≈ 400, aluminium ≈ 205–237, steel ≈ 50, concrete ≈ 1.4, glass ≈ 0.8–1, brick ≈ 0.7, plasterboard ≈ 0.21, wood ≈ 0.12–0.15, mineral wool ≈ 0.035–0.04, still air ≈ 0.026 | common textbook tables (see references) |
| Heat transfer coefficient h (W/(m²·K)) | free convection in air 2–25, forced air 25–250, water 100–20 000, boiling/condensing 2 500–100 000 | common textbook tables |
| Emissivity ε | matt paint ≈ 0.9, skin ≈ 0.95, polished aluminium ≈ 0.05 | common textbook tables |
| Stefan–Boltzmann constant σ | 5.670 × 10⁻⁸ W/(m²·K⁴) | CODATA |
| Surface films for walls | inside h ≈ 7.7, outside h ≈ 25 W/(m²·K) | simplified building-design values |
Checklist for any heat-transfer problem
- Which mechanisms act: conduction, convection, radiation, or several at once?
- Is it steady (temperatures fixed) or changing with time?
- Draw the heat path as resistances; decide which are in series and which in parallel.
- Use kelvin for radiation; differences in °C and K are the same.
- Sanity check: the largest resistance should take the largest temperature drop.
My notes
Private to this browser. Select any text above to highlight it.
This browser is blocking storage, so progress and notes will reset when you leave.