Module 2 · Strength of materials

Buckling of columns

Why long, slender parts under compression suddenly bow sideways at loads far below their crushing strength, and how end fixings change that.

Notes
On this page
  1. The idea
  2. Everyday intuition
  3. How it works
  4. Key formulas
  5. Worked example
  6. Where it is used
  7. Common misconceptions
  8. Self-check

The idea

A short, stubby block under compression fails by crushing. A long, slender fails differently: at a certain load it suddenly bows out sideways. This is . The load at which it happens, the , depends on stiffness (E and I) and length, not on the material’s strength. Doubling the length cuts it to a quarter.

Everyday intuition

Press down on a drinking straw: it suddenly kinks while the plastic is nowhere near crushed. Press on a short piece of the same straw and it holds much more. A ruler stood on end and pressed from the top bows out to one side long before it would break.

How it works

  1. A perfect column is in balance. A perfectly straight column, loaded exactly along its axis, can stay straight.
  2. But balance can be unstable. If something nudges it sideways a little, the compressive load now acts slightly off-centre and creates a bending moment that pushes it further out. The column’s bending stiffness tries to push it back.
  3. The tipping point. At low loads, stiffness wins and the column straightens again. At the critical load, the two exactly balance; above it, any small nudge grows. That is buckling.
  4. Stiffness, not strength. The result depends on E and I (bending stiffness) and length. A high-strength steel column buckles at the same load as a mild steel one of the same size, if it is slender.
  5. Ends matter. Fixed ends stop rotation and force a shorter “wave”, raising the critical load. A free end lets the column sway, lowering it. This is captured by the KLKL.
  6. Short or long? The (effective length divided by the ) tells you which failure comes first. Short columns crush (yield); long slender ones buckle. In between, real columns fail by a mix, and design codes use empirical curves.
pinned–pinned K = 1 fixed–fixed K = 0.5 fixed–pinned K ≈ 0.7 fixed–free K = 2

Fixed at one end, free at the other: K = 2.

Buckled shapes and effective length factors K for four end conditions. Buckled shapes for four end conditions. Original diagram drawn for this site. Tap labelled parts for an explanation.
Buckled shapes for four end conditions

Key formulas

Euler’s critical load for a slender, elastic, initially straight column:

Pcr=π2E I(KL)2P_{cr} = \frac{\pi^2 E\, I}{(K L)^2}

Critical stress and slenderness ratio:

σcr=PcrA=π2E(KL/r)2,r=IA\sigma_{cr} = \frac{P_{cr}}{A} = \frac{\pi^2 E}{(KL/r)^2}, \qquad r = \sqrt{\frac{I}{A}}

Effective length factors (ideal ends): pinned–pinned K=1K = 1; fixed–fixed K=0.5K = 0.5; fixed–pinned K≈0.7K \approx 0.7 (0.699); fixed–free K=2K = 2.

PcrP_{cr}
critical (Euler) buckling load N
EE
Young’s modulus Pa
II
smallest second moment of area of the section m⁴
KK
effective length factor (set by the end conditions) none
LL
actual unsupported length m
rr
radius of gyration (for a solid round bar, r = d/4) m
KL/rKL/r
slenderness ratio none

Worked example

Where it is used

  • Building columns, truss members and scaffolding are checked for buckling as well as stress.
  • Hydraulic cylinder rods and engine connecting rods are sized so they do not buckle when pushing.
  • Car jacks and screw jacks are limited by the buckling of the screw at full extension.
  • Thin-walled structures — drink cans, aircraft skins, ship plating — can buckle locally, so they use stiffeners.
  • Rail track can buckle sideways on hot days because of thermal compression.

Common misconceptions

Animated explanation of Euler buckling and effective length. Video: “Understanding Buckling” by The Efficient Engineer, embedded from YouTube. Watch on YouTube if the player does not load.

Self-check

Check The rod in the example is fixed at both ends instead (K = 0.5). What is its new Euler load?

Show answer

The effective length halves, so the load rises by a factor of 4: about 4×6.89=27.6 kN4 \times 6.89 = 27.6\ \text{kN}. (Still below the 78.5 kN crushing load, so buckling still governs.)

Check A flagpole is fixed into the ground and free at the top. What is its effective length factor, and is it better or worse than a pinned–pinned column of the same length?

Show answer

K = 2, so the effective length is twice the real length and the critical load is a quarter of the pinned–pinned value. Worse.

Check A rectangular strut is 10 mm × 40 mm. About which axis will it buckle?

Show answer

About the axis that gives the smaller I — it bends across the 10 mm thickness (the thin direction), just as a ruler bends flat-ways.

My notes

Private to this browser. Select any text above to highlight it.