Buckling of columns
Why long, slender parts under compression suddenly bow sideways at loads far below their crushing strength, and how end fixings change that.
0 deeper section(s) hidden.
On this page
The idea
A short, stubby block under compression fails by crushing. A long, slender fails differently: at a certain load it suddenly bows out sideways. This is . The load at which it happens, the , depends on stiffness (E and I) and length, not on the material’s strength. Doubling the length cuts it to a quarter.
Everyday intuition
Press down on a drinking straw: it suddenly kinks while the plastic is nowhere near crushed. Press on a short piece of the same straw and it holds much more. A ruler stood on end and pressed from the top bows out to one side long before it would break.
How it works
- A perfect column is in balance. A perfectly straight column, loaded exactly along its axis, can stay straight.
- But balance can be unstable. If something nudges it sideways a little, the compressive load now acts slightly off-centre and creates a bending moment that pushes it further out. The column’s bending stiffness tries to push it back.
- The tipping point. At low loads, stiffness wins and the column straightens again. At the critical load, the two exactly balance; above it, any small nudge grows. That is buckling.
- Stiffness, not strength. The result depends on E and I (bending stiffness) and length. A high-strength steel column buckles at the same load as a mild steel one of the same size, if it is slender.
- Ends matter. Fixed ends stop rotation and force a shorter “wave”, raising the critical load. A free end lets the column sway, lowering it. This is captured by the .
- Short or long? The (effective length divided by the ) tells you which failure comes first. Short columns crush (yield); long slender ones buckle. In between, real columns fail by a mix, and design codes use empirical curves.
Fixed at one end, free at the other: K = 2.
Key formulas
Euler’s critical load for a slender, elastic, initially straight column:
Critical stress and slenderness ratio:
Effective length factors (ideal ends): pinned–pinned ; fixed–fixed ; fixed–pinned (0.699); fixed–free .
- critical (Euler) buckling load N
- Young’s modulus Pa
- smallest second moment of area of the section m⁴
- effective length factor (set by the end conditions) none
- actual unsupported length m
- radius of gyration (for a solid round bar, r = d/4) m
- slenderness ratio none
Worked example
Where it is used
- Building columns, truss members and scaffolding are checked for buckling as well as stress.
- Hydraulic cylinder rods and engine connecting rods are sized so they do not buckle when pushing.
- Car jacks and screw jacks are limited by the buckling of the screw at full extension.
- Thin-walled structures — drink cans, aircraft skins, ship plating — can buckle locally, so they use stiffeners.
- Rail track can buckle sideways on hot days because of thermal compression.
Common misconceptions
Self-check
Check The rod in the example is fixed at both ends instead (K = 0.5). What is its new Euler load?
Show answer
The effective length halves, so the load rises by a factor of 4: about . (Still below the 78.5 kN crushing load, so buckling still governs.)
Check A flagpole is fixed into the ground and free at the top. What is its effective length factor, and is it better or worse than a pinned–pinned column of the same length?
Show answer
K = 2, so the effective length is twice the real length and the critical load is a quarter of the pinned–pinned value. Worse.
Check A rectangular strut is 10 mm × 40 mm. About which axis will it buckle?
Show answer
About the axis that gives the smaller I — it bends across the 10 mm thickness (the thin direction), just as a ruler bends flat-ways.