Enthalpy and heating at constant pressure
What enthalpy is, why flowing fluids carry it, sensible and latent heat, and how a kettle’s energy splits between warming and boiling.
0 deeper section(s) hidden.
On this page
The idea
, H = U + PV, is internal energy plus the work needed to push the fluid into place. It is the natural energy to track whenever pressure is constant or fluid flows through a device. Heating at constant pressure raises enthalpy by the heat added. Some heat raises the temperature (sensible heat); some changes the phase at fixed temperature ().
Everyday intuition
A pot of water on the hob: the temperature climbs steadily to 100 °C, then stays there for many minutes while it boils away. All that time the burner is still adding energy — it goes into turning liquid into steam.
How it works
- Why PV? To push a kilogram of fluid into a pipe against pressure P you must do work P v. A flowing fluid carries this ‘flow work’ along with its internal energy, so h = u + P v.
- Constant pressure heating. For a closed system at constant pressure, Q = ΔH. For a liquid or ideal gas without phase change, Δh = c_p ΔT.
- Phase change. At the (100 °C at 101.325 kPa), heat changes liquid to vapour without changing the temperature: Q = m h_fg.
- Pressure moves the boiling point. In a pressure cooker at about 200 kPa absolute water boils near 120 °C; on a high mountain it boils below 100 °C.
- Steam tables list h for water and steam at each pressure and temperature; engineers read values rather than integrating c_p.
Superheated steam warming.
Key formulas
Enthalpy:
Steady-flow energy equation:
- enthalpy J
- specific enthalpy J/kg
- specific heat at constant pressure J/(kg·K)
- latent heat of vaporisation J/kg
- heat rate into the device W
- power out of the device W
- mass flow rate kg/s
- specific enthalpy in and out J/kg
Worked example
Where it is used
- Boilers and heat exchangers: heat duty = mass flow × change in enthalpy.
- Steam heating and sterilising: condensing steam releases its large latent heat at a steady temperature.
- Air conditioning: cooling humid air also condenses water, which adds a latent-heat load.
Common misconceptions
Self-check
Check Why does a pressure cooker cook faster?
Show answer
Higher pressure raises the boiling point, so the water is hotter than 100 °C.
Check In a steady-flow heater, 0.5 kg/s of water rises by 20 K. What heat rate is needed?
Show answer
0.5 × 4.18 × 20 ≈ 42 kW.
Check During boiling, where does the added heat go?
Show answer
Into latent heat — changing liquid to vapour — not into temperature.