All labs · Module 4: Thermodynamics
Thermodynamic cycles on P–v and T–s diagrams
Change compression ratio and temperatures for Otto, Diesel, Brayton and Rankine cycles. The ideas behind it are explained in Otto and Diesel cycles.
Interactive lab
Thermodynamic cycles on P–v and T–s diagrams
What to notice
- Otto: raise the compression ratio and watch the efficiency climb. Raise the peak temperature instead: the loop grows (more work per kilogram) but the efficiency does not change.
- Diesel: at the same compression ratio it is less efficient than Otto, but diesel engines run at much higher ratios (15–22), so they win in practice.
- Brayton: efficiency depends only on the pressure ratio. Push the ratio high with a low turbine temperature and the net work collapses.
- Rankine: lower the condenser pressure and efficiency rises, but the steam leaving the turbine gets wetter.
- On the T–s diagram the area inside the loop is the net work per kilogram; compare every cycle with the Carnot limit between the same extreme temperatures.
Pressure (kPa) against specific volume (m³/kg)
Temperature (K) against specific entropy (kJ/(kg·K))
K
K
kPa
kPa
- Thermal efficiency
- —
- Carnot limit (same extremes)
- —
- Heat in
- —
- Net work
- —
- Extra
- —
Model assumptions and limits
- Gas cycles: cold-air standard — air is an ideal gas with constant cp = 1.005 kJ/(kg·K) and k = 1.4; compression and expansion are reversible and adiabatic (isentropic); combustion is replaced by heat added from outside.
- Gas cycles start at 100 kPa. Entropy is measured from state 1.
- Rankine: ideal simple cycle, saturated vapour into the turbine, saturated liquid out of the condenser, no superheat. Water properties come from a short saturation table (10 kPa to 10 MPa), interpolated, so values are approximate to about 1%.
- No friction, heat loss, pressure drop or mixing. Real engines and plants reach roughly half to three-quarters of these ideal efficiencies.